PLASMON-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, NOTIFICATION-TYPE FROM SNMPv2-SMI sysLocation FROM SNMPv2-MIB; plasmon MODULE-IDENTITY LAST-UPDATED "200512191130Z" ORGANIZATION "Plasmon" CONTACT-INFO " Plasmon Data Ltd Whiting Way Melbourn Herts SG8 6EN United Kingdom " DESCRIPTION "MIB for Plasmon products" ::= { enterprises 6191 } plmProducts OBJECT IDENTIFIER ::= { plasmon 1 } inas OBJECT IDENTIFIER ::= { plmProducts 1 } inasTrapArgs OBJECT IDENTIFIER ::= { inas 1 } inasTraps OBJECT IDENTIFIER ::= { inas 0 } -- Arguments to Archive Appliance traps plmLibDrive OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Object which describes a library drive" ::= { inasTrapArgs 1 } plmFreeMedia OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Object which contains the number of free media in the system" ::= { inasTrapArgs 2 } plmFreeSlots OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Object which contains the number of free slots in the system" ::= { inasTrapArgs 3 } plmFailedRAIDDrive OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Object which contains the id of a failed drive" ::= { inasTrapArgs 4 } plmBarcodeError OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Object which holds the barcode of a failed piece of media" ::= { inasTrapArgs 5 } plmTrapInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Object which holds the description of a trap" ::= { inasTrapArgs 6 } plmBarcode OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Object which holds the Media barcode" ::= { inasTrapArgs 7 } plmPool OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Object which holds the Media poolname" ::= { inasTrapArgs 8 } -- Traps used in Archive Appliance plmRAIDDegraded NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The RAID is running in degraded mode" ::= { inasTraps 1 } plmRAIDSyncComplete NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The RAID rebuild process has completed" ::= { inasTraps 2 } plmUPSCommsLost NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The Appliance has lost communication with the UPS" ::= { inasTraps 3 } plmUPSCommsRestored NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The Appliance has regained communications with the UPS" ::= { inasTraps 4 } plmUPSPowerLost NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The UPS has lost power" ::= { inasTraps 5 } plmUPSPowerRestored NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The UPS is being powered again" ::= { inasTraps 6 } plmUPSBatteryFailure NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The UPS battery is has failed" ::= { inasTraps 7 } plmLibDriveError NOTIFICATION-TYPE OBJECTS { plmTrapInfo, plmLibDrive } STATUS current DESCRIPTION "A drive in the library has failed" ::= { inasTraps 8 } plmLibChangerError NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The changer in the library has failed" ::= { inasTraps 9 } plmSSMReleaseFailure NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to release files" ::= { inasTraps 10 } plmSSMBackupFailure NOTIFICATION-TYPE OBJECTS { plmTrapInfo, plmBarcodeError } STATUS current DESCRIPTION "The backup failed" ::= { inasTraps 11 } plmSSMMediaInitFailure NOTIFICATION-TYPE OBJECTS { plmTrapInfo, plmBarcodeError } STATUS current DESCRIPTION "SSM failed to initialise a piece of media" ::= { inasTraps 12 } plmSSMMediaLevelLow NOTIFICATION-TYPE OBJECTS { plmTrapInfo, plmFreeMedia, plmFreeSlots } STATUS current DESCRIPTION "The system is running out of media" ::= { inasTraps 13 } plmSSMNoMedia NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The system has run out of media" ::= { inasTraps 14 } plmCacheFull NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The Appliance RAID cache has filled up to a critical level" ::= { inasTraps 15 } plmSSMBackupNoMedia NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The system has run out of media" ::= { inasTraps 16 } plmTestTrap NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Trap sent out to test SNMP configuration" ::= { inasTraps 17 } plmKeyProcessFailure NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "There has been a failure of a key process in the Archive Appliance" ::= { inasTraps 18 } plmSSMMediaFailure NOTIFICATION-TYPE OBJECTS { plmTrapInfo, plmBarcodeError } STATUS current DESCRIPTION "A piece of media has failed" ::= { inasTraps 19 } plmFanFailure NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "There has been a fan failure in the Archive Appliance" ::= { inasTraps 20 } plmFanOK NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Fan OK" ::= { inasTraps 21 } plmPSUFailure NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "There has been a power supply failure in the Archive Appliance" ::= { inasTraps 22 } plmPSUOK NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Power supply OK" ::= { inasTraps 23 } plmOfflineFileRequested NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "An operation resulted in requests for offline resources" ::= { inasTraps 24 } plmApplianceUpAndRunning NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Archive appliance booting process completed, It is up and running." ::= { inasTraps 26 } plmApplianceShutDown NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Archive appliance is shutting down..." ::= { inasTraps 27 } plmBackupFailedInsufficientMedia NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Backup failed: Estimated backup size larger than medium." ::= { inasTraps 28 } plmDirtyShutdownRecoveryStart NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Archive appliance was not shutdown properly, system is currently running recovery." ::= { inasTraps 29 } plmDirtyShutdownRecoveryComplete NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Archive appliance recovery complete." ::= { inasTraps 30 } plmApplianceCheckSuccess NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Archive Appliance database(FSC) database test successful." ::= { inasTraps 31 } plmApplianceCheckFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Archive Appliance database(FSC) database test fail." ::= { inasTraps 32 } plmSSMNoBackupMedia NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "There is no media in the backup pool." ::= { inasTraps 33 } plmSSMSelfTest NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "SNMP trap mechanism self test PASSED." ::= { inasTraps 34 } plmSSMUnknownVolumesDetected NOTIFICATION-TYPE OBJECTS { plmTrapInfo, plmBarcode } STATUS current DESCRIPTION "Unknown volumes detected" ::= { inasTraps 35 } plmDrivesNotAvailable NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "No drives are available for migration" ::= { inasTraps 402 } plmOMMCandidate NOTIFICATION-TYPE OBJECTS { plmTrapInfo, plmBarcode, plmPool } STATUS current DESCRIPTION "OMM Candidate availibility" ::={ inasTraps 308 } plmOMMCandidateEjected NOTIFICATION-TYPE OBJECTS { plmTrapInfo, plmBarcode, plmPool } STATUS current DESCRIPTION "OMM Candidate ejected from library" ::={ inasTraps 309 } plmOMMCandidateReturned NOTIFICATION-TYPE OBJECTS { plmTrapInfo, plmBarcode, plmPool } STATUS current DESCRIPTION "OMM Candidate returned to library" ::={ inasTraps 310 } -- Traps used for SNAZOS NetWorking( ID 1000~1099) plmNETBondStart NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The bond device has started." ::= { inasTraps 1000 } plmNETBondRemove NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The bond device has been removed." ::= { inasTraps 1001 } plmNETDisable NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The interface in a bond is disabled because its link is down." ::= { inasTraps 1002 } plmNETActivate NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The interface in a bond has been activated." ::= { inasTraps 1003 } plmNETDown NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The network interface is down." ::= { inasTraps 1004 } plmNETInterfaceEmpty NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "No active interface is in a bond." ::= { inasTraps 1005 } plmNETInterfaceUp NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The network interface is up." ::= { inasTraps 1006 } -- Traps used for SNAZOS Raid( ID 1100~1199) plmRAIDStartFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to start a RAID." ::= { inasTraps 1101 } plmRAIDStartOk NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The RAID has successfully been started ." ::= { inasTraps 1102 } plmRAIDStopFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to stop a RAID." ::= { inasTraps 1104 } plmRAIDStopOk NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The RAID has successfully been stopped." ::= { inasTraps 1105 } plmRAIDRemoveOk NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The faulty disk has been successfully removed from a RAID." ::= { inasTraps 1106 } plmRAIDRemoveDiskFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to remove the faulty disk from a RAID." ::= { inasTraps 1107 } plmRAIDAssignOk NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The hot-spare disk has been successfully assigned to a degraded RAID." ::= { inasTraps 1108 } plmRAIDAssignFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to assign a hot-spare disk to the degraded RAID." ::= { inasTraps 1109 } plmRAIDRemoveDiskOk NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The faulty disk has been removed from system RAID." ::= { inasTraps 1111 } plmRAIDAssignOK NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The system spare disk has been assigned to system RAID." ::= { inasTraps 1115 } plmRAIDDiskFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The disk has failed on a RAID, disabling device. You may need to replace the faulty disk with a new disk." ::= { inasTraps 1117 } plmRAIDHasDegraded NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The RAID has degraded. Please check and ensure a hotspare disk has been added to the RAID." ::= { inasTraps 1118 } plmRAIDSyncFinished NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The RAID has finished resynchronization." ::= { inasTraps 1119 } -- Traps used for SNAZOS User and Group Management( ID 1200~1299) plmUGLoginFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Security Warning: A user failed to authenticate." ::= { inasTraps 1200 } plmUGLogined NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Web Administration: A user has logged in." ::= { inasTraps 1201 } -- Traps used for SNAZOS Device( ID 1300~1399) plmDEVForceRescanFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Rescan could not add device back to kernel. You may need to reboot your system." ::= { inasTraps 1301 } plmDEVForceRescanOk NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The device has been successfully rescanned." ::= { inasTraps 1302 } plmDEVRemove NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The disk has been removed." ::= { inasTraps 1303 } plmDEVPrefail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Self-check failed, the device needs to be replaced soon." ::= { inasTraps 1304 } plmDEVFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The disk failed." ::= { inasTraps 1306 } plmDEVSetFaulty NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The disk is set faulty." ::= { inasTraps 1313 } plmDEVSetOk NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The disk is set ok." ::= { inasTraps 1316 } -- Traps used for SNAZOS Environment Monitoring( ID 1400~1499) plmEVCPUVoltage NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The core voltage of CPU is incorrect." ::= { inasTraps 1400 } plmEVCPUTemp NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The CPU temperature is too high. Please check cooling or turn off your system." ::= { inasTraps 1401 } plmEVFanLow NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The fan speed is too slow. Please check if the fan is broken." ::= { inasTraps 1402 } plmEVBoardTempHigh NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The board temperature is too high. Please check cooling or shut down the system." ::= { inasTraps 1403 } plmEVSystemFull NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The system volume is nearly full, trying to recover space by deleting logs." ::= { inasTraps 1404 } plmEVVolumeFull NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The data volume is nearly full." ::= { inasTraps 1405 } -- Traps used for SNAZOS LVM( ID 1500~1599) plmLVMNameConflict NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The logical volume name is conflict. You may change the offline logical volume's name." ::= { inasTraps 1501 } plmLVMStartLvFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to start the Logical volume: mount failure. Please try to diagnose the volume." ::= { inasTraps 1502 } plmLVMStartSnapshotFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to start the snapshot volume: mount failure." ::= { inasTraps 1503 } plmLVMStopLvFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to stop the logical volume: unmount failure. You may need to reboot your system." ::= { inasTraps 1504 } plmLVMStopSnapshotFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to stop the snapshot volume: unmount failure. You may need to reboot your system." ::= { inasTraps 1505 } plmLVMVgFaulty NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The pool is faulty: one member RAID is dead or missing." ::= { inasTraps 1506 } plmLVMVgInactivate NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The pool is inactive: pool name conflict." ::= { inasTraps 1507 } plmLVMSnapshotResizeOk NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The snapshot on a storage pool has been resized." ::= { inasTraps 1508 } plmLVMSnapshotResizeFail NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to resize the snapshot on a storage pool. You may need to delete some other snapshots or volumes on the same pool." ::= { inasTraps 1509 } plmLVMSnapshotDeleted NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The snapshot is deleted." ::= { inasTraps 1510 } plmLVMSnapshotCreated NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The snapshot is created by schedule." ::= { inasTraps 1511 } plmLVMSnapshotDead NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The snapshot on a pool is dead because the snapshot size is too small." ::= { inasTraps 1512 } plmLVMSnapshotDeleteOk NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The faulty snapshot volume on a pool is deleted." ::= { inasTraps 1517 } plmLVMSnapshotDeleteFailed NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The faulty snapshot volume on a pool is on use and cannot be deleted." ::= { inasTraps 1518 } plmLVMSnapshotCreateFailed NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Failed to create snapshot for a volume." ::= { inasTraps 1519 } -- Traps used for SNAZOS Replication( ID 1600~1699) plmRepJobFinished NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The replication job successfully finished." ::= { inasTraps 1600 } plmRepJobFailed NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The replication job failed." ::= { inasTraps 1601 } plmRepJobStarted NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The replication job started." ::= { inasTraps 1602 } -- Traps used for SNAZOS Share Management( ID 1700~1799) -- Traps used for SNAZOS Miscellaneous system management( ID 1800~1899) plmMSMModify NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The service is started/stopped." ::= { inasTraps 1800 } plmMSMTimeServer NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The time of the server is synchronized with the domain controller before it joins the AD." ::= { inasTraps 1801 } plmMSMLoseDomain NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The connection to the domain is down, the Samba shares maybe inaccessible and domain users and groups can not be retrieved from the domain either." ::= { inasTraps 1802 } -- Traps used for SNAZOS (Others Left)( ID 1900~1999) plmOTDeleteLog NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "Some log files have been deleted." ::= { inasTraps 1900 } plmOTServiceRestartOk NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "A service was not running correctly, successfully started the service." ::= { inasTraps 1901 } plmOTServiceRestartFailed NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "A service was not running correctly, failed to start the service." ::= { inasTraps 1902 } plmXFSShutDown NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "XFS file system was shutdown by some errors." ::= { inasTraps 1903 } -- Traps used for SNAZOS UPS( ID 2000~2100) plmUPSCommsHasLost NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The SNAZ has lost communication with the UPS" ::= { inasTraps 1000 } plmUPSCommsHasRestored NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The SNAZ has regained communications with the UPS" ::= { inasTraps 1003 } plmUPSPowerHasLost NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The SNAZ UPS has lost power" ::= { inasTraps 1009 } plmUPSPowerHasRestored NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The SNAZ UPS is being powered again" ::= { inasTraps 1014 } plmUPSBatteryHasFailed NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The SNAZ UPS battery has failed" ::= { inasTraps 1015 } plmUPSShutDown NOTIFICATION-TYPE OBJECTS { plmTrapInfo } STATUS current DESCRIPTION "The SNAZ UPS is shutting down/rebooting the system" ::= { inasTraps 1020 } END